AU1500EXM (Indirect type)
AU1500EXM
  • 1. HMI control panel
  • 2. Automatic 8 speeds paddy husk feeding system for reduce biomass consumption.
  • 3. Automatic 8 speeds blower to ensure completion combustion.
  • 4. Automatic ash discharge system
MODELAU1500EXM
Husk consumption, Kg/hr (100KG/m3)MAX.420
MIN.60
Thermal output, Kcal/hrMAX.1,027,242
MIN.146,749
Equivalent thermal energy of diesel, L/hrMAX.117
MIN.17
Air volume & temperature increment, cmm / ℃1,200 / 47
※ Heat efficiency, %70
Ash output, kg/hr (maximum)84
Control systemHMI/ touch screen control system
Dimensions (mm)Height10,411
Length8,028
Width5,841
Power ConsumptionVoltage, V220V/ 380V/415V/440V, 50Hz/60Hz,(3 phases) 
Rated power (kW)Husk feeding auger1.5
Inner ash auger1.5
Outer ash auger1.5
Flue gas gan7.5
Air lock rotary valve0.4
Combustion blower3.75
Maximum power consumption, kW16.15 (21.53 HP)
Safety devices Furnace over heat alarm 
Padddy husk tank fire alarm
Air pressure alarm
Furance pressure regulator
Motor thermal breakers
Pneumatic cleaning nozzles 
Inspection door open alarm
Ash cleaning active alarm
Residual husk discharge shutter
Standard EquipmentFurnace main body
Heat Exchanger
Touch screen control box
Furance pressure regulator
Cyclone
Flue gas fan
Residual husk collecting tank

※ Heat efficiency may be affected by heat loses caused by duct length, ambient temperature, husk feeding rate and husk thermal energy.