| MODEL | AI800 | AI900 | AI1000 | |||
| Husk consumption, Kg/hr (100KG/m3) | MAX. | 168 | 240 | 420 | ||
| MIN. | 50 | 60 | 120 | |||
| Thermal output, Kcal/hr | MAX. | 588,000 | 796,636 | 1,394,114 | ||
| MIN. | 175,000 | 199,159 | 398,318 | |||
| Equivalent thermal energy of diesel, L/hr | MAX. | 67 | 91 | 158 | ||
| MIN. | 20 | 23 | 45 | |||
| Air volume & temperature increment, cmm / ℃ | 500/35 Each | |||||
| ※ Heat efficiency, % | 95 | |||||
| Ash output, kg/hr (maximum) | 34 | 48 | 84 | |||
| Control system | HMI/ touch screen control system | |||||
| Dimensions (mm) | Height | 5265 | 6362 | 7446 | ||
| Length | 3901 | 4210 | 5437 | |||
| Width | 2344 | 2152 | 2646 | |||
| Power Consumption | Voltage, V | 220V/ 380V/415V/440V, 50Hz/60Hz,(3 phases) | ||||
| Rated Power (kW) | Husk feeding auger | 1.5 | 1.5 | 1.5 | ||
| Inner ash auger | 0.75 | 0.75 | 0.75 | |||
| Outer ash auger | 0.75 | 0.75 | 0.75 | |||
| Combustion air blower | 1.5 | 1.5 | 1.5 | |||
| Maximum power consumption, kW | 3.4 ( 4.5 HP) | 4.5 ( 6.0 HP) | 4.5 ( 6.0 HP) | |||
| Safety devices | Furnace pressure regulator | |||||
| Furnace pressure regulator | ||||||
| Motor thermal breakers | ||||||
| Backfire alarm, husk auger | ||||||
| Emergency stop | ||||||
| Standard equipment | Main body | |||||
| Husk feeding shutter | ||||||
| Husk feeding hopper | ||||||
| Touch screen control box | ||||||
| Ash tank | ||||||
※ Heat efficiency may be affected by heat loses caused by duct length, ambient temperature, husk feeding rate and husk thermal energy.